Loading

Tableau Server degraded - Non-Interactive and Interactive Microservice Container in error state

Data pubblicazione: Feb 24, 2026
Descrizione
When starting Tableau Server, all processes are running except :
 
Tableau Server Interactive Microservice Container in error state
Tableau Server Non-Interactive Microservice Container in error state

Also the user will see a "blank page" when trying to connect to Tableau Server.

Cause

The Non-Interactive and Interactive Microservice processes were not able to use the loopback address, because of a special character.
Risoluzione
Review the hosts file (/etc/hosts), and see if there is a special character incorrectly specified with the IP address.

Example of a hosts file with a special character (backslash) :
\127.0.0.1       localhost
 
Risorse aggiuntive

Tableau Server example logs :

/logs/tabadminagent
Unexpected HTTP error response from tomcat manager (403): Forbidden

 

/logs/noninteractive/tomcat_noninteractive_node1-0.log
Invalid character found in method name. HTTP method names must be tokens


How to find and edit Windows Hosts file