Loading

Flow Fails With Error Logicexception Details: Logicaloptosqlqueryfunction::impl:visittuples Not Implemented - Possible Reason Could Be Unable To Create A Fallback Plan When Temp Table Creation Fails

Julkaisupäivä: Apr 22, 2025
Kuvaus

The flow fails with the error below:

"LogicException details: LogicalOpToSqlQueryFunction::Impl:VisitTuples not implemented - possible reason could be unable to create a fallback plan when temp table creation fails - check if there is permission to create temp tables.

Cause

The user does not have permission on Snowflake schema to create a temp table.
Ratkaisu
Work with the database administrator to grant permission for the user to create temp tables on Snowflake schema when running Tableau Prep Builder or Tableau Prep Conductor.