Unable to load table in Tableau Desktop connecting to Trino Database

Date de publication: Feb 21, 2025
Description

After successfully connecting to Trino by using Presto connector, the table is failed to be loaded

Unexpected Error
Error executing query
Error Code: FAB9A2C5

Cause

When connecting to Trino Database, Tableau uses presto-jdbc-0.272, which is not compatible with Trino.
Résolution
1. In C:/Program Files/Tableau/Drivers, remove presto-jdbc-0.272.1.jar
2. If you are connecting to Trino, download the appropriate driver from the Trino page.  The Trino driver only works in Tableau versions 2021.3, 2021.2.2, 2021.1.5, 2020.4.8, 2020.3.12, and above.
 