Loading

Extract Refresh Via Tableau Bridge Fails With "VConDownstreamExtractsWithWarnings" Message using Extract from Desktop 2023.1

Publiceringsdatum: Feb 23, 2026
Beskrivning

After creating an extract using Tableau Desktop 2023.1 or newer, and using a Tableau Bridge version released prior to 2023.1 to refresh the extract, the refresh fails with the following error:

VConDownstreamExtractsWithWarnings

Cause

There is a compatibility issue between Tableau Desktop 2023.1 and the old version of Tableau Bridge.
Lösning

Option 1:

Use Tableau Desktop 2022.4 or an older version to create the extract of the data source.


Option 2:

Upgrade Tableau Bridge to 2023.1 or newer version. For more details, see Upgrade Bridge.  Tableau Bridge downloads are available from the Tableau release website.