Tableau Server TSM Initialization Terminated at Step 34 of 40 Finalizing the Topology Failed

게시 일자: Aug 21, 2026
상세 설명

After Tableau Server installation, TSM initialization failed at step 34 of 40 with the error below.

This job failed due to unexpected error: 'ServiceOperationTimeoutException'

One or more services failed to reach their expected state. node1:

  • apigateway_0.20262.26.0603.1643: Failed to start. Current status: DOWN
  • backgrounder_0.20262.26.0603.1643: Failed to reach requested state. Current state: DISABLE_FAILED
  • backgrounder_1.20262.26.0603.1643: Failed to start. Current status: DOWN
  • vizportal_0.20262.26.0603.1643: Failed to start. Current status: DOWN

Initialization terminated at step 34 of 40: Finalizing the topology failed.

솔루션

Third-party security software (antivirus) may interfere with Tableau Server's internal processes during topology deployment, causing service timeouts. 
Try one of the following options, then run TSM initialization again: 

  1. Temporarily stop the antivirus software.

  2.  Configure appropriate antivirus exclusion policies as detailed in the following Knowledge Base article.
    Improve Tableau Server Performance and Stability by Using Antivirus Exclusions