Loading
Ongoing maintenance for Salesforce HelpRead More

Prep Conductor Fails to Start in Multi-Node Tableau Server

Publish Date: Sep 8, 2026
Description

Tableau Prep Conductor (flowprocessor) fails to start and remains in STATUS_UNAVAILABLE in a multi-node Tableau Server environment on Windows.

Snipped Log:

・TSM log (tabadminagent_node*.log):
License check did not succeed for flowprocessor_0 STATUS_UNAVAILABLE, 
detail message: License check did not succeed 

・Flowprocessor log (nativeapi_flowprocessor_*.log): 
ActivationServiceClient: max retries failed and last response contained an error code '14': 'DNS resolution failed for [node-hostname]:[port]: C-ares status is not ARES_SUCCESS qtype=AAAA name=[node-hostname] is_balancer=0: Domain name not found'
* Note: [node-hostname] represents the actual hostname or Fully Qualified Domain Name (FQDN) of the node

Cause: DNS Name Resolution Failure

While the OS-level standard name resolution functions normally, Tableau Server's internal process fails when attempting to resolve hostnames via DNS under specific network configurations. As a result, license verification with ActivationService cannot complete during Tableau Prep Conductor's startup, causing it to remain in the STATUS_UNAVAILABLE state.

Resolution

Add the IP address and hostname of each node to the hosts file on all nodes to enable local name resolution without relying on DNS.
Perform the following steps on all nodes in the cluster.

Step 1: Add all node IP addresses and hostnames to the hosts file on each node 

  1. Open Notepad or another text editor using Run as Administrator.
  2. Open the following file:
       C:\Windows\System32\drivers\etc\hosts 
  3. Append entries for all nodes in the cluster to the end of the file:
       [Node 1 IP address]    [Node 1 hostname or FQDN]
       [Node 2 IP address]    [Node 2 hostname or FQDN]
       [Node 3 IP address]    [Node 3 hostname or FQDN]
       (Add additional lines as needed for each node.)
  4. Save the file.

Step 2: Restart Tableau Server

  1. On the initial (primary) node, run the following command:
       tsm restart
  2. Wait for all processes to start. This may take several minutes.

Step 3: Verify Prep Conductor status

  1. Check the process status using the TSM admin console or the following command:
       tsm status -v
  2. Confirm that the flowprocessor status shows as "Active."

Additional Notes:

  • The hosts file entries must be added on all nodes in the cluster. Adding entries on only some nodes may not resolve the issue.
  • If IP addresses are assigned dynamically via Dynamic Host Configuration Protocol (DHCP), assign static IP addresses to all nodes to prevent future recurrence.
  • When adding or replacing nodes in the future, update the hosts file entries on all nodes accordingly.
  • For environments utilizing a forward proxy with net.properties  configured, please refer to the following article.
     Tableau Prep Conductor Process in a STATUS_UNAVAILABLE State After Configuring The net.properties File