Tableau Prep Conductor Fails to Start with STATUS_UNAVAILABLE Due to DNS Resolution Failure

Publiseringsdato: Nov 18, 2026
Beskrivelse

Tableau Prep Conductor (flowprocessor) fails to start and remains in STATUS_UNAVAILABLE in Tableau Server environment on Windows.

Snipped Log:

・TSM log (tabadminagent_node*.log):
License check did not succeed for flowprocessor_0 STATUS_UNAVAILABLE, 
detail message: License check did not succeed 

・Flowprocessor log (nativeapi_flowprocessor_*.log): 
ActivationServiceClient: max retries failed and last response contained an error code '14': 'DNS resolution failed for [node-hostname]:[port]: C-ares status is not ARES_SUCCESS qtype=AAAA name=[node-hostname] is_balancer=0: Domain name not found'
* Note: [node-hostname] represents the actual hostname or Fully Qualified Domain Name (FQDN) of the node

Cause: DNS Name Resolution Failure

While the OS-level standard name resolution functions normally, Tableau Server's internal process fails when attempting to resolve hostnames via DNS under specific network configurations. As a result, license verification with ActivationService cannot complete during Tableau Prep Conductor's startup, causing it to remain in the STATUS_UNAVAILABLE state.

Løsning

Add the IP address and hostname of the Tableau Server node (or all nodes in a multi-node deployment) to the hosts file to enable local name resolution without relying on DNS. Perform the following steps on all nodes in the cluster.

Step 1: Add all node IP addresses and hostnames to the hosts file on each node 

  1. Open Notepad or another text editor using Run as Administrator.
  2. Open the following file:
       C:\Windows\System32\drivers\etc\hosts 
  3. Append entries for all nodes in the cluster to the end of the file:
       [Node 1 IP address]    [Node 1 hostname or FQDN]
       [Node 2 IP address]    [Node 2 hostname or FQDN]
       [Node 3 IP address]    [Node 3 hostname or FQDN]
       (Add additional lines as needed for each node.)
  4. Save the file.

Step 2: Restart Tableau Server

  1. Run the following command (on the initial node in a multi-node environment): 
       tsm restart
  2. Wait for all processes to start. This may take several minutes.

Step 3: Verify Prep Conductor status

  1. Check the process status using the TSM admin console or the following command:
       tsm status -v
  2. Confirm that the flowprocessor status shows as "running"

Additional Notes:

  • For multi-node deployments, the hosts file entries must be added on all nodes. Adding entries on only some nodes may not resolve the issue.
  • If IP addresses are assigned dynamically via Dynamic Host Configuration Protocol (DHCP), assign static IP addresses to all nodes to prevent future recurrence.
  • When adding or replacing nodes in the future, update the hosts file entries on all nodes accordingly.
  • For environments utilizing a forward proxy with net.properties  configured, please refer to the following article.
     Tableau Prep Conductor Process in a STATUS_UNAVAILABLE State After Configuring The net.properties File
Knowledge-artikkelnummer

005390460

 
Laster
Salesforce Help | Article