Loading

WDC 2.0 Refresh Error "No active connection to the data source" on Linux Bridge 2026.2

Udgivelsesdato: Oct 5, 2026
Beskrivelse

Issue

When attempting to run extract refreshes for data sources utilizing Web Data Connector (WDC) 2.0 on Tableau Bridge for Linux, the refresh fails.
The following error is recorded:
Failed to refresh data source: due to the following error: There is no active connection to the data source.


Note: Extract refreshes for WDC 2.0 continue to work successfully on Tableau Bridge versions 2026.2.0 and 2026.2.1 for Windows.

Environment

  • Tableau Bridge for Linux 2026.2.0, 2026.2.1
  • Web Data Connector (WDC) 2.0

 

Løsning
To resolve this issue, use one of the following temporary workarounds or plan for the long-term migration.

Temporary Workarounds
:
*Before applying Option 1 or Option 2 of the workarounds below, ensure that the target Web Data Connector (WDC) 2.0 data source has been published separately as a standalone published data source and is not embedded within a workbook. Starting in Tableau Cloud 25.1, WDC 2.0 data sources that remain embedded in a workbook are restricted from being scheduled for refresh via Tableau Bridge. (For more details, refer to WDC datasources embedded in workbooks fail to refresh in Cloud).

  • Option 1: Use Tableau Bridge 2026.2 on Windows
    • Perform the extract refreshes using Tableau Bridge on Windows, which is unaffected by this issue.
  • Option 2: Downgrade Tableau Bridge for Linux
    • Downgrade the Tableau Bridge client on Linux to version 2025.1, where the extract refresh functionality is confirmed to work.
  • Option 3: Refresh Extracts manually in Tableau Desktop
    • Manually refresh the extract within Tableau Desktop and republish the data source.

Long-Term Recommendation:
As Web Data Connector (WDC) 2.0 has been deprecated since the Tableau 2023.1 release, plan to migrate the data connection to a supported method (such as WDC 3.0 or another native connector) as soon as possible.
Note: Tableau Bridge does not support WDC 3.0. If you migrate to WDC 3.0, you must plan for alternate connection and refresh methods.

Yderligere ressourcer

For more information,
See Connectivity with Bridge in Tableau Help.

  • Bridge is not able to connect to data from Web Data Connector 3.0.
  • The Web Data 2.0 is deprecated as of the 2023.1 release.
  • Tableau doesn’t support connectors or other programs written to interface with the WDC API.

Web Data Connector 2.0 in Tableau Help.

  • The Web Data 2.0 connector is deprecated as of the 2023.1 release. You can use the connector until it’s been retired. Once the connector is retired, it’s removed from the Tableau user interface and any data sources using the connector will no longer work as expected.
Vidensartikelnummer