Connecting to Published Multifact Data Sources on Tableau Server with "Bad Datasource Path" Error

Date de publication: Aug 31, 2026
Description
Environment / Product
  • Tableau Server (Linux)
  • Tableau Desktop Connected to Published data source on Tableau server (Linux)
  • Affects data sources with multifact (multi-base-table) relationships
  • Occurs regardless of VizData Service (VDS) feature flag state

 

Issue / Symptom
When connecting to a published data source containing multifact tables (a data source with more than one base table), the connection fails with:

"An error occurred while communicating with the data source / Bad Datasource path"

This occurs in both Tableau Desktop and Web Authoring. Disabling VizData Service (VDS) feature flags does not resolve the issue, since multifact relationships require VDS with no legacy fallback path.
 
Cause
Multifact data source connections require the VizData Service to construct and validate temporary data source file paths during session initialization. If the Tableau Server data directory (default: /var/opt/tableau/) has been replaced with a symbolic link (for example, moved to a separate partition due to disk space constraints), VDS cannot resolve the symlinked path when creating these temporary file handles — resulting in the "Bad Datasource path" error.

Symbolic links pointing the tableau_server data directory elsewhere (e.g., /var/opt/tableau/tableau_server → /opt/tableau_server) are an unsupported configuration when VDS-dependent features (like multifact data sources) are in use.
 
Résolution
  1. Move the Tableau Server data directory back to the default location, /var/opt/tableau/ (do not use a symlink).
  2. Remove the symbolic link.
  3. Restart Tableau Server, including admin services.
  4. Re-publish and reconnect to the multifact data source to confirm the connection succeeds.