Loading

Google Analytics 4 connector fails to refresh after upgrade to Tableau 2026.3, 2026.2.4, 2025.3.11, or 2025.1.21

Date de publication: Nov 3, 2026
Description

After upgrading to Tableau 2026.3, 2026.2.4, 2025.3.11, or 2025.1.21 workbooks and data sources built on the Google Analytics 4 (GA4) connector fail to refresh. This is expected: the current GA4 connector was built on the WDC 3.0 framework run in the Extensible Protocol Server (EPS) process, which Tableau is phasing out as part of platform modernization and security uplift. Starting with Tableau 2026.3 and all other October 2026 maintenance releases, the connector is disabled by default across all Tableau on-premise products.

 

A new native GA4 connector is shipping in late 2026 and full code removal of the original connector is planned for a Tableau 2027.1.

 

Disable Phasing:

 

  • Tableau Server: disabled by default in Tableau 2026.3, 2026.2.4, 2025.3.11, and 2025.1.21.

  • Tableau Desktop: disabled by default in Tableau 2026.3, 2026.2.4, 2025.3.11, and 2025.1.21.

  • Tableau Prep Builder: disabled by default in Tableau 2026.3

  • Tableau Cloud: disabled early 2027.

Résolution

Migrate to the new native Google Analytics 4 connector shipping in late 2026. If Tableau was upgraded before the new GA4 connector is available, or if upgrading to Tableau 2026.3.x is currently not possible, the original connector can be temporarily re-enabled until the new connector is available, or upgrading Tableau is feasible, and migration is complete. The new connector, like the original connector, provides native integration with the GA4 API and supports extract-based connections only; live connections are not available.

 

  1. Upgrade to Tableau 2026.3.x (fall 2026). The new GA4 connector is not compatible with prior versions of Tableau.

  2. In Tableau Desktop, test the new native GA4 connector against non-production workbooks. Temporarily re-enable the original connector, if needed, to assist with the following steps.

  3. Re-create each affected data source using the new connector with the same GA4 credentials (OAuth 2.0) and replace data sources.

  4. It may be necessary to rebuild calculations or dashboard layouts that were created using the original data source.

  5. Validate data accuracy against the original connector wherever possible.

  6. Republish workbooks to Tableau Server or Tableau Cloud using the new connector.

Temporary Workaround

Customers who need additional time may re-enable the original GA4 connector in Tableau using the instructions below. The capability to re-enable the connector will be removed in Tableau 2027.1, so please plan migration accordingly.

 

Tableau Server

 

  1. Open a command line terminal on a Tableau Server node and run the following commands:

tsm configuration set -k features.DisableEPSGoogleAnalytics4 -v false

tsm configuration set -k features.EPSRuntimeEnable -v true

tsm configuration set -k features.EPSVizQLStart -v true

tsm pending-changes apply

  1. Choose free ports. Run tsm topology list-ports and note the Node and Instance of every vizqlserver process. Each one needs two ports that:

  1. Aren't listed for that node anywhere in the list-ports output. TSM rejects ports assigned to other services even if nothing is listening on them, such as JMX ports.

  2. Aren't in use on the machine (optional): netstat -ano | findstr :<port> returns nothing (Linux: ss -ltn | grep :<port>).

  3. On multi-node clusters, are in the port range open between nodes (TSM's default is 8000–9000). The same ports can be reused on different nodes.

  1. Assign the ports. Stop the server first; otherwise every set-ports command restarts it. Run both commands (eps.main and eps.static_server) for every VizQL Server instance on every node:

tsm stop

tsm topology set-ports -n node1 -pn vizqlserver:eps.main          -i 0 -pv 8940 --ignore-prompt

tsm topology set-ports -n node1 -pn vizqlserver:eps.static_server -i 0 -pv 8941 --ignore-prompt

tsm topology set-ports -n node1 -pn vizqlserver:eps.main          -i 1 -pv 8942 --ignore-prompt

tsm topology set-ports -n node1 -pn vizqlserver:eps.static_server -i 1 -pv 8943 --ignore-prompt

(same for each remaining instance)

tsm start

Each command takes 1–2 minutes even with the server stopped. If one fails with "Port N is already in use by service instance ...", choose another port and run it again before tsm start

  1. Check that it worked. Running tsm topology list-ports | findstr eps should list both eps.main and eps.static_server for every VizQL Server instance

  2. Repeat steps 2–4 if you add VizQL Server processes or upgrade Tableau Server.

 

Tableau Desktop 

 

Windows:

  1. Open the Windows Registry Editor.

  2. Navigate to the HKEY_CURRENT_USER\Software\Tableau\Tableau {Version} registry

  3. Add a Debug key if one does not exist.

  4. Add the string value FeatureOverrideOn to the Debug key

  5. In the Value data field, add EPSRuntimeEnable

  6. Add another string value FeatureOverrideOff to the Debug key

  7. In the Value data field, add DisableEPSGoogleAnalytics4

  8. Close and Reopen Tableau Desktop

 

Mac:

  1. Launch Terminal

  2. Run the following commands replacing {version} with the appropriate Tableau version being used (e.g. com.tableau.Tableau-2025.3)

    1. defaults write com.tableau.Tableau-{version}.plist Debug.FeatureOverrideOn "EPSRuntimeEnable"

    2. defaults write com.tableau.Tableau-{version}.plist Debug.FeatureOverrideOff "DisableEPSGoogleAnalytics4"

 

Tableau Prep Builder

 

Step 1: Find your Prep build number

  1. Open the Tableau Prep Builder app folder:

    • Mac: In Finder, open Applications, right-click Tableau Prep Builder, and choose Show Package Contents.

    • Windows: In File Explorer, go to C:\Program Files\Tableau\Tableau Prep Builder <version> (for example, Tableau Prep Builder 2026.2). If it isn't there, right-click the Prep shortcut and choose Open file location.

  2. Open package.json in a text editor:

    • Mac: Open Contents → Resources → app, then open package.json in TextEdit.

    • Windows: Open resources\app, right-click package.json, and choose Open with → Notepad.

  3. Find the "version" line and copy the number. For example: "version": "26.24.26.1006.0600",
    This is your build number. It looks like NN.NN.NN.NNNN.NNNN and is not the 2026.x version shown in the app name.

Step 2: Create the settings file

  1. Quit Tableau Prep Builder.

  2. Go to your Prep repository folder:

    • Mac: In Finder, press ⇧⌘G and go to ~/Documents/My Tableau Prep Repository

    • Windows: In File Explorer, paste %USERPROFILE%\Documents\My Tableau Prep Repository into the address bar and press Enter.

  3. Create a folder named Settings there, if one doesn't already exist.

  4. Open a plain-text editor:

    • Mac: Open TextEdit and press ⇧⌘T to switch to plain text.

    • Windows: Open Notepad.

  5. Paste the flags you want to set. Put one flag on each line, in quotes, with a comma after every line except the last.

{

  "jvmArgs": [

    "--loom.nativeFeature.DisableEPSGoogleAnalytics4=false",

    "--loom.nativeFeature.EPSRuntimeEnable=true"

  ]

}

  1. Save it in the Settings folder as settings-BUILD_NUMBER.json, replacing BUILD_NUMBER with the number from Step 1.

    • Mac: If TextEdit asks, choose Use .json.

    • Windows: In Save As, set Save as type to All files (*.*) and Encoding to UTF-8. Otherwise Notepad saves the file as .json.txt.

  2. Open Tableau Prep Builder as usual. The flags are now on.

New native connector features

  • Native Tableau integration (no WDC 3.0 dependency).

  • OAuth 2.0 authentication with Google accounts.

  • Access to GA4 API dimensions and metrics.

  • Extract-based connections only.

Timeline

  • October 2026: GA4 connector disabled by default in Tableau 2026.3, 2026.2.4, 2025.3.11, and 2025.1.21 releases

  • Tableau 2026.3.x (late 2026): New native GA4 connector to be released

  • Early 2027: Original GA4 connector disabled in Tableau Cloud

  • Tableau 2027.1: The workaround to re-enable the original GA4 connector will no longer be available.

Related resources

Google Analytics 4 connector documentation

 

Numéro d’article de la base de connaissances