Loading

Scheduler booking on LWR Experience Cloud site shows "Unknown error occurred" on the Review Service Appointment screen

Fecha de publicación: Oct 16, 2026
Descripción
  • Guest users on an LWR Experience Cloud site can't finish a Scheduler booking through a custom appointment flow.
  • The Review Service Appointment screen (runtime_appointmentbooking:lwrReviewIO) shows "Unknown error occurred" with a spinner as soon as it loads.
  • Flow navigation succeeds (HTTP 201). The request that loads the ServiceAppointment page-layout fields in guest context returns HTTP 501 with no readable body.
  • Guest profile layout assignment and permissions are correct, and the issue reproduces in Production and in sandbox.
  • It started after a Salesforce release that renamed an internal Scheduler API (Unified Scheduling → Workforce Scheduling). LWR sites that weren't republished still referenced the previous API name
Solución
  1. In Experience Builder, open the affected LWR site.
  2. If the site is deactivated or in a stale state, reactivate it.
  3. Click Publish to republish the site.
  4. Open the booking page in a new private browser window. 
  5. Run the booking flow through to the Review Service Appointment screen and confirm it loads.
  6. Repeat for every LWR site that uses Scheduler booking flows, including sandbox and UAT sites.
Recursos adicionales
  • Republish LWR Scheduler sites after major releases.
  • Test booking flows in a sandbox on the release preview. Engineering confirmed the same behavior appears in sandbox, so it can be caught before Production.
     