Loading
The Trailblazer Community is now read-only Read More

Marketing Cloud data extension records are missing in Data Cloud even though the data stream shows "Success"

Publish Date: Nov 3, 2026
Description
This Article Applies to
  • Data Cloud data streams using the Salesforce Marketing Cloud connector on a data extension.
  • Refresh mode Upsert with Data Extract Method Datetime CDC.
  • Numeric CDC streams that use a system-defined extract column (such as an identity column) are not affected by delayed data. Numeric CDC is append-only: it extracts newly inserted records and advances its HWM, and it does not capture updates to existing rows. If the numeric column is not system-defined, a row with a lower value can be inserted later and arrive late, so check how your extract column is populated.

Symptoms

  • Record counts in the Marketing Cloud DE exceed the Data Cloud data lake object (DLO) counts.
  • A record changed in the DE still shows an old value in Data Cloud.
  • Scheduled refreshes report Success with 0 records processed or 0 records added.
  • The dropped-rows table is empty, indicating the rows were never extracted.
  • A manual "Refresh Now" brings in a batch of previously missing records.
  • Segments or activations built on the data are incomplete (for example, send logs or consent records).

Cause

  • You choose a datetime field in the DE as the extract field (for example DeltaDatetime, EventDateUTC, LastModifiedDate, or Run_ts).
  • After each run, Data Cloud stores the highest value of that field. This is the high water mark (HWM).
  • Subsequent incremental runs extract rows whose extract-field value is greater than or equal to (>=) the HWM. This is the Datetime CDC default.
  • A row written with an extract-field value older than the HWM is skipped silently, with no error or alert.

Common ways rows end up behind the HWM

  • Late-arriving data: rows with an older business timestamp load after newer rows were already extracted.
  • Backdated or bulk-set timestamps: an automation or SQL query sets the date field to a past value instead of the real write time.
  • Inconsistent time zones: queries write the date field in different time zones instead of UTC.
  • Historical loads or backfills into a DE that is already being extracted.
  • The chosen field is not a true "last modified" value and is not updated when a row changes.

Datetime CDC trusts the date field you choose. If that field does not always increase as rows are written, rows can be skipped.

 

Resolution

Step 1: Confirm the issue.

  • In Marketing Cloud, note the DE record count and pick a sample record missing in Data Cloud.
  • In Data Cloud, open the data stream, then Details. Confirm Data Extract Method = Datetime CDC, Refresh Mode = Upsert, and the extract field name.
  • Compare the sample record's extract-field value with the stream's last processed time/HWM. If it is older than the HWM, the record was skipped by design.
  • Check the dropped rows for the stream. An empty table means the rows were never extracted.
  • Check the refresh history. Repeated 0-record successes while the DE grows is a strong indicator. Note that 0 records can be legitimate when there are no deltas.

Step 2: Choose the right approach for your data.

  • If the DE receives delayed, backfilled, or late-arriving data and rows are not overwritten, Datetime CDC is not suitable. Migrate to Salesforce CDC (Option 3).
  • If the DE is regularly overwritten (all rows dropped and reinserted), use Full refresh.
  • For a one-time incident with suspected delayed records, use Option 1 or Option 2.


Option 1: On-demand refresh ("Refresh Now")

  • For Marketing Cloud upsert streams, run an Incremental refresh or a Full refresh.
  • A refresh resets the data stream watermark and re-extracts all data once, like a Full extract. After that, only deltas are picked up.
  • A refresh does not reset the Data Factory Utility (DFU) driver watermark. If the missing rows still don't appear after a refresh, open a case so Engineering can investigate (see Option 2).
  • Use Incremental to add missing rows without deleting existing data. Use Full when removed rows must also disappear from Data Cloud.
  • This is a one-time fix. If the DE keeps receiving delayed data, the same rows can be missed again.
Option 2: Watermark reset by Salesforce Support or Engineering
  • Use this only for a one-time incident where delayed records are suspected, or when Refresh Now did not bring the rows back. Resetting the DFU driver watermark requires an Engineering investigation.
  • Open a Support Case with the stream name, DE name, extract field, and the earliest date of missing data. Your DE contents are not changed.
  • Do not change the HWM yourself. Modifying the HWM for DFU drivers can affect extraction. Support or Engineering should handle it.

Option 3 (permanent fix): Migrate to Salesforce CDC.

Salesforce CDC does not compare dates. A hidden column named _VersionStamp (based on the SQL built-in RowVersion) is added to the DE. It auto-increments when a row is inserted or updated. Each run extracts rows above the last version processed, so historic, backdated, or late-arriving rows are not missed.

Two ways to migrate

  • Existing DE: Engineering adds _VersionStamp through an internal API. Open a case. Migration is currently Engineering-led.
  • New DE: create a new DE from the Salesforce CDC DE template. The field is included automatically. Import data and create a new stream.

Migration steps (existing DE, coordinated with Support)

  • Open a Support Case requesting the Salesforce CDC migration for the specific DE and stream.
  • Pause all imports and automations that write to the DE and the data stream for the migration window. Adding the field briefly locks the DE; pausing avoids import failures and data loss.
  • Engineering adds the _VersionStamp field.
  • Once the field exists and the DFU driver updates, Data Cloud switches the stream to Salesforce CDC automatically, even if the UI still shows Numeric or Datetime.
  • Resume imports and the stream.
  • Verify counts and sample records.

What to expect

  • A one-time full upsert of existing rows, because every row receives a version. The cost equals fully upserting the DE. Plan the window and credits.
  • No risk of duplicates, because the upsert uses the primary key.
  • If an automation rewrites a datetime column on every row daily, every row gets a new version and Salesforce CDC extracts the whole DE each run. Consider Full refresh instead if rows are dropped and reinserted.
  • Deletes in Marketing Cloud are not propagated by incremental refreshes. Schedule periodic Full refreshes if deletes matter.
  • The extract mode cannot currently be changed from the data stream UI after creation. Ingest Mode Edits are planned.
  • Testing: a side-by-side comparison on a copy of the DE is limited, because a query activity that fills the copy has no HWM memory. A one-time load test on a clone DE is the realistic test.

Prevention best practices

  • Use Salesforce CDC for DEs that receive late-arriving, backdated, bulk-loaded, or multi-source data, if rows are not constantly overwritten.
  • If you remain on Datetime CDC: use a field set to the real write time in UTC that only increases. Avoid mixed time zones, do not backfill old-dated rows into an actively extracted DE, and do not use an immutable business event time if rows can arrive late.
  • Monitor for silent failures: compare DE and DLO counts on a schedule. Investigate streams that report Success with 0 records while the source grows. Spot-check recent records after bulk automations.
  • If segments, suppression, or consent depend on this data, treat gaps as high priority. Missing opt-out rows can cause messaging to people who opted out.
  • Test changes on a clone DE and stream before modifying production.