You are here:
Enable Error Logging for Integration Procedures
Enable error logging to capture detailed information about failed Integration Procedure steps. Omnistudio writes all Integration Procedure errors to the OmniComponentErrorLog sObject records.
-
To enable error logging for Integration Procedures, create an Omni Interaction
Configuration setting.
-
From Setup, enter Omni Interaction Configuration in the Quick Find box, and then select
Omni Interaction Configuration. - Click New Omni Interaction Configuration.
-
For label and name, enter
ErrorLoggingEnabledwithout space and without changing the case. - Enter true as the value.
- Save your changes.
The error details and response for a failed step are sent to the Input field on the
OmniComponentErrorLogsObject record. The error message is sent to the ErrorMessage field. You can also send custom error messages to the ErrorMessage field on theOmniComponentErrorLogsObject. -
From Setup, enter Omni Interaction Configuration in the Quick Find box, and then select
-
View detailed information about failed Integration Procedure steps in the
OmniComponentErrorLogsObject records:- From Setup, find Users, and then select Profiles.
- Select a profile.
- In Tab Settings, set Omni Component Error Logs to Default On.
- From the App Launcher, select Omni Component Error Logs.